Product parameters:
- Measurement of AC / DC voltage and current, resistance, diodes, continuity, capacitance
- Automatic polarity display
- Frequency measurement of currents and low voltages (low voltage) up to 1000 V in the range from 40 to 400 Hz
- Measurement of low voltage (low voltage) frequency in the range from 10 Hz to 1 MHz
- Measurement capacitance rating 60nF to 60mF
- Temperature measurement -40 to + 1000 ° C with closed type K thermocouple
- Proportional (relative) voltage and capacitance measurement
- Multi-segment display and audible / visual alarm
- Protection against voltages greater than 1000 V in the ranges
- NCV function - non-contact detection of live conductors
- LoZ V function ~ measurement with low input impedance (approx. 2kO) of the device
- INRUSH function - measurement of transients up to 100 ms - initial current at power on up to 3000A with additional flexible loop
- LPF ACV function - AC voltage measurement with filter nf (approx. ( reason) for voltage and capacity measurement: yes
- data hold: yes
- low battery indication: yes
- auto power off: yes
- 1.5V battery power (R03): 2pcs
- backlight screen size: 43 x 45 mm
- dimensions no.: 272 x 81 x 43.5 mm
- product net weight: 450g
- product color: red and gray
Technical parameters:
1. AC measuring current (ranges / resolution / accuracy):
60.00A / 0.010A / 40Hz ~ 400Hz ± (2.0% + 9)
600.0A / 0.100A / 40Hz ~ 400Hz ± (2.0% % + 5)
1000.0A / 1A / 40Hz ~ 400Hz ± (2.0% + 5)
- the accuracy of frequency monitoring for AC current measurement in the range of 40 to 400Hz is ± (0.1% + 3) at 0.1 Hz resolution
- overload protection at 1000A
2. AC inrush current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / 40Hz ~ 400Hz ± (10.0% + 10)
600.0A / 0.100A / 40Hz ~ 400Hz ± (10.0% + 10)
1000.0A / 1A / 40Hz ~ 400Hz ± (10.0% + 10)
- overload protection at 1000A
with flexible current loop
30.00A / 0.010A / 40Hz ~ 400Hz ± (10.0% + 10)
300.0A / 0.100A / 40Hz ~ 400Hz ± (10.0% + 10)
3000.0A / 1A / 40Hz ~ 400Hz ± (10.0% + 10)
- overload protection at 3000A
3. DC current measurement (ranges / resolution / accuracy):
60.00A / 0.010A / ± (2.0% + 5)
600.0A / 0.100A / ± (2.0% + 5)
1000.0A / 1A / ± (2.0% + 5)
- overload protection at 1000A
4. AC voltage measurement (range / resolution / accuracy):
6000V / 0.001V / 40Hz ~ 400Hz ± (1.2% + 3 )
60.00V / 0.010V / 40Hz ~ 400Hz ± (1.2% + 3)
600.0V / 0.100V / 40Hz ~ 400Hz ± (1.0% + 8)
1000.0V / 1V / 40Hz ~ 400Hz ± (1.0% + 8)
- precision monitoring function when measuring AC voltage in the range of 40 Hz to 400 Hz ± (0.1% + 3) with a resolution of 0.1 Hz
- overload protection at 1000 Vrms
- input impedance of approx. 10MGO
5. LPF AC V (measuring with low frequency filter approx. 2.5 kHz)
(range / resolution / precision):
600.0 V / 0.1 V / ± (2.0% + 5)
1000.0 V / 1 V / ± (2.0% + 5)
- overload protection at 1000 Vrms
- input impedance of approximately 10MGO
6. LPF AC V (measuring with low input impedance of approximately 2kO)
(range / resolution / accuracy):
600.0V / 0.1V / ± (2.0% + 5)
1000.0V / 1V / ± (2.0 % + 5)
- overload protection at 1000Vrms
- input impedance of approx. 2kO
7. Measurement voltage rating (range / resolution / accuracy):
600.0mV / 0.100mV / ± (0.8% + 3)
6000 V / 0.001V / ± (0.5% + 3)
60.00V / 0.010V / ± (0.5% + 3)
600.0V / 0.100V / ± (0.5% + 3)
1000.0V / 1V / ± (0.5% + 3)
- input impedance of approx . 10MO
- overload protection at 1000Vrms
8. Resistance measurement (ranges / resolution / accuracy):
600.0O / 0, 1O / ± (1.0% + 3)
6,000kO / 0.001kO / ± (1.0% + 2)
60.00kO / 0.01kO / ± (1.0% + 2)
600.0kO / 0.1kO / ± (1.0% + 2)
6,000MO / 0.001MO / ± (2.0% + 8)
60.00MO / 0.01MO / ± (2.0 % + 8)
- overload protection at 1000 Vrms
- open circuit voltage of about 1V
9. Circuit continuity inspection:
- if the measured resistance is less than 30O, the alarm bell sounds continuous circuit
- with measured resistance greater than 70O , the open circuit signal yes no buzzer
- uncertainty in the range of 31O to 69O
- open circuit voltage about 1.0 V
- measurement in the range of 600O , with a resolution of 0.1O
- overload protection at 1000 Vrms
10. Diode measurement:
- in the forward direction , the voltage drop across the semiconductor junction is less than or equal to l to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8 V
- open circuit voltage of about
of 3.0 V - measurement in the range of 6000 V, at a resolution of 0.001 V
11. Capacitance measurement (ranges / resolution / accuracy):
60, 00 nF / 0.01nF / ± (4.0% + 25)
600.0nF / 0.1nF / ± (4.0% + 5)
6,000µF / 0.001µF / ± (4.0% + 5)
60.00µF / 0.01µF / ± (4.0% + 5)
600.0µF / 0.1µF / ± (4.0% + 5)
6,000mF / 0.001mF / ± 10.0% + 9
60.00mF / 0.01mF / ± 10.0% + 9
- overload protection a 1000 Vrms
12. Temperature measurement (ranges / resolution / accuracy):
-40 ° C to + 300 ° C / 0.1 ° C / ± 1.0 ° C + 20
+ 300 ° C to + 1000 ° C / 1 ° C / ± (1.0% + 2)
-40 ° F to + 572 ° F / 0.2 ° F / ± 1.0% + 40
+ 573 ° F to + 1832 ° F / 1 ° F / ± (1.0% + 4)
13. Frequency measurement and duty cycle (fill) (ranges / resolution / precision):
frequency: 10 H z to 1 MHz / 0.01 Hz to 1 kHz / ± (0.1% + 3)
fill: 10% to 99.0% / 0.1% / ± (2.6% + 7)
- Note 1) Measurement sensitivity:
10Hz to 100kHz: 250mVrms = input amplitude = 20V RMS
100kHz to 10MHz: 600mV RMS = input amplitude = 20V RMS
- Note 2) Filling measurement (work rate) is only applicable for square wave 10Hz to 10kHz:
2Vpp = input amplitude = 20V pp
- overload protection at 1000 Vrms
14. Non-contact electric field sensor (NCV):
- allows detect live wires - as the intensity of the detected voltage increases, more bar graph segments will be displayed and with a higher value the buzzer will sound frequently and the LED will start flashing